Power quality analysis · Cape Town and the Western Cape

Detailed Power Quality Investigation

Find the cause of electrical problems and define a vendor-neutral fix.

When the Power Quality Screening in an Energy Loss Audit identifies a problem, or when you already suspect one, a detailed investigation finds the cause and defines the fix. We measure where the problem shows up, trace it to its source and specify the corrective measures. We do not sell the equipment.

Common symptoms

Power quality problems rarely announce themselves. They show up as failures, trips and heat that nobody can explain. If any of these sound familiar, measurement is the place to start.

  • Nuisance tripping. Breakers and earth leakage devices that trip without a clear fault.
  • Overheating cables or transformers. Harmonic currents and unbalance add heat without doing useful work.
  • Failed capacitors. Power factor correction capacitors that fail early, often through resonance with existing harmonics.
  • Damaged electronics. Drives, power supplies and controllers that fail after voltage dips or swells.
  • Flickering lighting. Rapid voltage fluctuations from large motor starts, welding or a weak supply.
  • Unexplained motor failures. Voltage unbalance and harmonics raise motor temperatures and shorten winding life.
  • Disputes with the utility about supply quality. You need measured evidence of the voltage you receive.

What the investigation covers

  1. Simultaneous logging at several distribution boards. We log the main incomer and the affected boards at the same time, so causes and effects line up.
  2. Root-cause analysis and identification of problem loads. We trace harmonics, unbalance and voltage events to the loads or supply conditions that cause them.
  3. Transformer and cable derating assessment. We check whether harmonic currents and unbalance mean transformers and cables must carry less load than their rating.
  4. Vendor-neutral specification for harmonic filters or detuned power factor correction. A specification based on your measured conditions, so any supplier can quote against it.
  5. A formal supply quality report suitable for submission to the utility. Voltage quality assessed against NRS 048-2 from a measurement campaign designed for that purpose, and customer emissions assessed against NRS 048-4 where required.

How it relates to the Energy Loss Audit

Every Energy Loss Audit includes a Power Quality Screening at the main incomer. The screening shows whether a problem exists and how serious it is. The investigation often follows when the screening rates a parameter as Action, but you can also appoint it on its own, without an audit.

Power Quality Screening compared with a Detailed Power Quality Investigation
AspectPower Quality ScreeningDetailed Power Quality Investigation
PurposeShows whether a problem exists and how serious it isFinds the cause and defines the fix
Measurement pointsThe main incomerSeveral distribution boards at the same time
OutputA Pass, Watch or Action rating for each parameterRoot causes, corrective measures and, where required, a specification for tender
Utility disputesIndicative results onlyA formal supply quality report
How it is chargedIncluded in every Energy Loss AuditQuoted separately on a written scope

Swipe the table sideways to see both columns.

What you receive

  • An investigation report with findings tied to measured evidence.
  • Root-cause findings for each problem identified.
  • Corrective measures, ranked by urgency and cost.
  • Where required, a vendor-neutral specification suitable for tender.
  • A debrief meeting to walk through the findings and agree next steps.

Find the cause before you buy the fix

Tell us what is tripping, failing or overheating. We will reply with a proposed written scope for the investigation.

Request an investigation